Description
Özellikler ve sipariş bilgisi
Ordering Information
Main Unit
Power supply voltage | Order code |
---|---|
24 VCD | K6PM-THMD-EIP |
Infrared thermal sensor
Resolution | Order code |
---|---|
32 × 32 | K6PM-THS3232 |
EtherNet/IP communications cable recommended parts
Use a Category 5 or higher STP cable (shielded twisted pair cable).
Cable with Connectors
Item | Recommended manufacturer | Cable length (m) | Order code | |
---|---|---|---|---|
Wire Gauge and Number of Pairs: AWG26, 4-pair Cable Cable Sheath material: LSZH |
Cable with Connectors on Both Ends (RJ45/RJ45) Standard RJ45 plug type Cable color: Yellow |
OMRON | 0.3 | XS6W-6LSZH8SS30CM-Y |
0.5 | XS6W-6LSZH8SS50CM-Y | |||
1 | XS6W-6LSZH8SS100CM-Y | |||
2 | XS6W-6LSZH8SS200CM-Y | |||
3 | XS6W-6LSZH8SS300CM-Y | |||
5 | XS6W-6LSZH8SS500CM-Y | |||
Wire Gauge and Number of Pairs: AWG22, 2-pair Cable |
Cable with Connectors on Both Ends (RJ45/RJ45) Rugged RJ45 plug type Cable color: Light blue |
OMRON | 0.3 | XS5W-T421-AMD-K |
0.5 | XS5W-T421-BMD-K | |||
1 | XS5W-T421-CMD-K | |||
2 | XS5W-T421-DMD-K | |||
5 | XS5W-T421-GMD-K | |||
10 | XS5W-T421-JMD-K |
Cable/Connector
Part name | Manufacturer | Order code |
---|---|---|
Cable | Hitachi Metals, Ltd. | NETSTAR-C5E SA 0.5 × 4P |
RJ45 connector | Panduit Corporation | MPS588-C |
Industrial switching hub (recommended parts)
Recommended manufacturer | Appearance | Specifications | Order code | ||
---|---|---|---|---|---|
Function | No. of ports | Failure detection function | |||
OMRON | Packet priority control (QoS): EtherNet/IP control data priority Failure detection: Broadcast storm, LSI failure detection 10/100BASE-TX, Auto-Negotiation |
3 | Not possible | W4S1-03B | |
5 | Not possible | W4S1-05B | |||
5 | Possible | W4S1-05C | |||
Cisco Systems, Inc | Consult the manufacturer. https://www.cisco.com/ |
||||
Contec USA, Inc. | Consult the manufacturer. https://www.contec.com/us/ |
||||
Phoenix Contact USA | Consult the manufacturer. https://www.phoenixcontact.com/online/portal/pc |
Specifications
Main Unit
Ratings
Item | K6PM-THMD-EIP | |
---|---|---|
Power supply | Power supply voltage | 24 VDC |
Allowable operating voltage range | 85% to 110% of the power supply voltage | |
Power supply frequency range | – | |
Power consumption | 1.6 W max. | |
Input | Compatible sensor | K6PM-THS3232 |
Number of connected K6PM sensors | 31 units | |
Output | Output form | Transistor output |
Number of outputs | 3 points | |
Rated voltage | 24 VDC | |
Maximum current | 50 mA | |
Ambient operating temperature | –10 to +55 °C (with no condensation or freezing) | |
Ambient storage temperature | –20 to +65 °C (with no condensation or freezing) | |
Ambient operating humidity | 25% to 85% (with no condensation) | |
Storage humidity | 25% to 85% (with no condensation) | |
Exterior color | Black | |
Case material | PC UL94-V0 | |
Altitude | 2,000 m max. | |
Applicable wires | Stranded wires, solid wires, or ferrules | |
Applicable wire size | 0.25 to 1.5 mm2 (AWG24 to AWG16) | |
Wire insertion force | 8 N max. for AWG20 wire | |
Screwdriver insertion force | 15 N max. | |
Wire stripping length | 8 mm
, 10 mm, 12 mm |
|
Recommended Flat-blade Screwdriver | XW4Z-00B | |
Current capacity | 10 A (per pole) | |
Number of insertions | 50 times | |
Weight | Approx. 200 g | |
Mounting | DIN Track mounting | |
Screw Mounting | ||
Dimensions | 45 (W) × 90 (H) × 90 (D) mm | |
Setting method | Communications settings from software tool | |
Other functions | Display value selection, Main Unit error and K6PM sensor error output, setting parameters initialization, running time |
|
Accessories | Instruction manual, Software Tool (thermal condition monitoring tool) license number |
Characteristics
Item | K6PM-THMD-EIP | ||
---|---|---|---|
Temperature measurement range | The temperature measurement range is described in the thermal sensor (K6PM-THS3232) performance. |
||
Measurement temperature accuracy | The measurement temperature accuracy is described in the thermal sensor (K6PM-THS3232) performance. | ||
Sampling cycle for the sensor | Approx. 1 second/Unit | ||
External trigger | External contact input specifications |
Short circuit: Residual voltage 1.5 V or less | |
Open: Leakage current 0.1 mA or less | |||
Short circuit current | Approx. 7 mA | ||
Alarm | Measurement parameters | Current temperature, differential temperature, sensor internal temperature | |
Expression method | Transistor output, alarm bar display | ||
Number of variables | Two threshold values per segment (Threshold 1 and Threshold 2) | ||
Threshold setting range | 0.0 to 999.9°C (0.0 to 999.9°F) | ||
Hysteresis | 3.0°C width (5.4°F width) | ||
Resetting method | Manual resetting
or automatic resetting (switching) |
||
LCD display | 7-segment digital displays and individual indicators | ||
Display resolution | 0.1°C | ||
Applicable standards | Approved standards | UL61010-1 (Listing) installation location: Pollution level 2, South Korean Radio Law | |
Conforming standards | RCM | ||
EMC | EN61326-1 (EMI: Class A EMS: Industrial Location) | ||
Recommended fuse | T2A, time lag, high shut-off capacity | ||
Insulation resistance | 20 MΩ min. Between all external terminals and the case Between all power supply terminals and all other terminals Between all RS-485 communications terminals, and all external trigger input terminals, all transistor output terminals and all Ethernet ports |
||
Dielectric strength | 2,000 VAC for 1 minute Between all external terminals and the case Between all power supply terminals and all other terminals Between all RS-485 communications terminals, and all external trigger input terminals, all transistor output terminals and all Ethernet ports |
||
Vibration resistance | Frequency: 10 to 55 Hz, 0.35-mm single amplitude in X, Y, and Z directions (10 sweeps of 5 min each) | ||
Shock resistance | 150 m/s2, 3 times each in X, Y, and Z axes, 6 directions | ||
Degree of protection | IP20 | ||
Warranty period | 1 year | ||
Indicators | Alarm bar | Red, yellow, and green | |
MS and NS | Red and green | ||
Ethernet Communicaitons | Supported services | EtherNet/IP (tag data link or CIP message communications) BOOTP client Modbus TCP |
|
Physical layer | 100 Base-TX | ||
Transmission specifications |
Transmission speed | 100 Mbps | |
Transmission medium | Twisted pair cable (with shield: STP): Category 5 or higher | ||
Transmission distance | 100 m max. (distance between hub and node) | ||
Tag data link | Class1 | Supported. | |
Connection resource | 4 | ||
Packet interval (RPI) | 1,000 to 10,000 ms | ||
Timeout value | Multiples of RPI (4 times, 8 times, 16 times, 32 times, 64 times, 128 times, 256 times, 512 times) | ||
Connection type | Point To Point Connection (fixed) | ||
Explicit message | Class 3 | Supported | |
UCMM | Supported | ||
Number of clients that can communicate at one time with UCMM |
2 | ||
Modbus TCP | Number of clients that can be connected simultaneously |
2 | |
Factory default values | IP address | 192.168.250.30 | |
Subnet mask | 255.255.255.0 | ||
The default gateway | 0.0.0.0 | ||
IP address setting method | Static IP address |
Indicator
Symbol | Name | Color | Status | Operating condition |
---|---|---|---|---|
MS | Module Status | Green | Lit. | Normal status |
Red | Lit. | One of the following fatal errors (Main Unit internal error)
|
||
Flashes at 1-s intervals. | One of the following conditions
|
|||
– | Not lit. | No power supply | ||
NS | Network Status | Green | Lit. | Tag data link or message connection established |
Flashes at 1-s intervals. | No tag data link or message connection established | |||
Red | Lit. | IP address duplication status | ||
Flashes at 1-s intervals. | The connection has timed out, or the BOOTP server connection error state | |||
– | Not lit. | No power supply |
Transistor output
Name | Description | |
---|---|---|
Transistor Output 1 | Threshold 1 excess output of comprehensive alarm. | If threshold 1 exceeded occurs for the comprehensive alarm, transistor output 1 remains OFF and transistor output 2 remains ON.If threshold 2 exceeded occurs for the comprehensive alarm, both transistor output 1 and transistor output 2 turn OFF. (Normally closed type) |
Transistor output type can be set to Normally Closed or Normally Open. | ||
Transistor Output 2 | Threshold 2 excess output of comprehensive alarm. Transistor output type can be set to Normally Closed or Normally Open. |
|
Transistor Output 3 | Main Unit error and K6PM-TH sensor error output
The output type of transistor output 3 is fixed as Normally closed. |
Status | Transistor output 3 | |
---|---|---|
Status of Main Unit | Status of infrared thermal sensor | |
Operating | OFF | |
Main Unit internal error | ||
In monitoring mode | Before data acquisition | ON |
Normal | ||
K6PM-TH sensor communications error or sensor type error | OFF | |
The detection of the K6PM-TH sensor angle deviation | ||
Temperature measurement range exceeded | ||
Running time error | ||
K6PM-TH sensor search mode or K6PM-TH sensor position adjustment mode |
Before data acquisition | ON |
Normal | ||
K6PM-TH sensor communications error or sensor type error | ||
The detection of the K6PM-TH sensor angle deviation | ||
Temperature measurement range exceeded | ||
Running time error | OFF |
Measured value display
Measurement level | Methods for checking | ||
---|---|---|---|
Main Unit (display) | Software tool | Communicaitons | |
Temperature of each segment and sensor internal temperature |
The segment display of each sensor can be switched on the Main Unit front-panel. |
Can be checked on the Monitoring sensor screen. |
|
Differential temperature per segment from the K6PM-TH sensor internal temperature |
Not supported | Not supported | Not supported |
Temperature of each infrared thermal sensor |
Not supported | The past maximum value can be monitored on the Monitoring K6PM screen. |
Not supported |
Temperature of each pixel | Not supported | The temperature can be displayed when the cursor is placed on the thermal image on the Monitoring sensor screen. |
|
Alarms of each Main Unit (Alarms of all infrared thermal sensors connected to the Main Unit) |
The occurrence of an alarm can be checked on the alarm bar. |
The occurrence of an alarm can be checked on the Device List of K6PM screen. |
The occurrence of an alarm can be checked from the Main Unit status. |
Infrared thermal sensor
Ratings
Item | K6PM-THS3232 | |
---|---|---|
Power supply | Power supply voltage | 24 VDC |
Allowable operating voltage range | 85% to 110% of the power supply voltage | |
Power supply frequency range | – | |
Power consumption | 0.4 W max./Unit at 24 VDC | |
Ambient operating temperature | –10 to +55 °C (with no condensation or freezing) | |
Storage temperature | –20 to +65 °C (with no condensation or freezing) | |
Ambient operating humidity | 25% to 85% (with no condensation) | |
Storage humidity | 25% to 85% (with no condensation) | |
Exterior color | Black | |
Case material | PC UL94-V0 | |
Altitude | 2,000 m max. | |
Applicable wires | Stranded wires or solid wires | |
Applicable wire size | 0.25 to 1.5 mm2 (AWG24 to AWG16) | |
Current capacity | 8 A (per pole) | |
Weight | 50 g max. | |
Mounting | Mounting
Screw Mounting |
|
Dimensions | 43 × 60 × 25.1 mm (W×H×D) Terminals not included | |
Accessories | Instruction manual, mounting bracket, magnet (for positioning) |
Performance
Item | K6PM-THS3232 | |
---|---|---|
Temperature measurement | Temperature measurement range | Temperature measurement range: 0.0°C to 200.0°C (32.0°F to 392.0°F) |
Detection resolution | 32 × 32 (1,024 pixels) | |
Temperature accuracy | ±5°C (at an ambient temperature of 25°C) | |
Emissivity | 0.94 | |
Reproducibility | 1°C (at an ambient temperature of 25°C) | |
Temperature drift | 0.15°C | |
Viewing angle [FOV] | 90° × 90° | |
Warmup time | 15 minutes | |
Other functions | Over temperature measurement range | Temperature: 200.0°C or higher, sensor internal temperature: 80°C or higher |
Angle deviation detection | Angle deviations of 5° (typ) min. and those that continue for 3 seconds min. can be detected. | |
Output | Communications method | RS-485 communications |
Maximum cable length | 500 m | |
Applicable standards | Approved standards | UL61010-1 (listing) installation location: Pollution degree 2 |
Korean Radio Waves Act | ||
Conforming standards | RCM | |
EMC | EN61326-1 (EMI: Class A EMS: Industrial Location) Measured temperature fluctuation range: ±6°C |
|
Recommended fuse | T2A, time lag, high shut-off capacity | |
Insulation resistance | 20 MΩ min. Between all terminals and the case |
|
Dielectric strength | 1,000 VAC for 1 minute Between all terminals and the case |
|
Vibration resistance | Frequency: 10 to 55 Hz, 0.35-mm single amplitude in X, Y, and Z directions (10 sweeps of 5 min each) | |
Shock resistance | 150 m/s2, 3 times each in 6 directions along 3 axes | |
Degree of protection | IP20 | |
Indicators | Power indicator | Green (when power is on: lit, when power is not on: off) |
Communications indicator | Orange (when communications are performed: Lit, when communications are not performed: Not lit) | |
Alarm indicator | Red (when a sensor error occurs: Lit, when an angle deviation is detected: Flashing) |
Software tool
Item | Specification | |
---|---|---|
Project | Number of files that can be created | No limit |
Sampling cycle of infrared thermal sensor: 1 to 99 | 1 to 99 minutes, or 1 to 99 hours (default value: 1 minute) | |
Logging | Supported file format | Tab-delimited text file format |
Measurement interval | Sampling cycle | |
Log file unit | A new file for every 1,440 rows (excluding the header) regardless of the sampling interval | |
1 Number that can be registered in the project |
Number of Main Unit | 5 Units max. |
Files to create | The following are created in the installation folder \cfg:
Refer to Details of the File to be Created for details. |
|
Photo image file format that can be read and displayed | JPG/JPEG format | |
Temperature alarm threshold automatic setting | Supported |
Details of the file to be created
File type | Extension | Description | Save position by default |
---|---|---|---|
Project file | .ini | Text file including the following:
|
C:\Program Files\OMRON\Thermal Condition Monitoring Tool\cfg |
Configuration file | .ini | Text file including the following (file name = fixed as “app.ini”):
|
C:\Program Files\OMRON\Thermal Condition Monitoring Tool\cfg |
Log file | .txt | A file is created for each Main Unit. It is text file format, so it can be used by other applications. |
The log file location is as follows: C:\Program Files\OMRON\Thermal Condition Monitoring Tool\ log\[Main Unit number (2 digits)] |
Operating Environment of the Software tool
Item | Description |
---|---|
OS | Windows 7, Windows 8.1, Windows 10 (32 bit/64 bit) (JP/EN) |
CPU | 2.4 GHz or more, 32 bit or 64 bit processor |
Memory | 4 GB min. |
Disk reserved area capacity | 64 GB min. |
Monitor resolution | 1024 × 768 (XGA), High Color 16 bit or more |
.NET Framework | . NET Framework 4.7.2 |
Others | LAN port: For network connection |