Item
|
F3S-TGR-CL2_-0__
|
F3S-TGR-CL4_-0__
|
Sensor type
|
Type 2
|
Type 4
|
Protective height
|
150 mm to 2,400 mm
|
Operating range
(short setting or long setting)
|
F3S-TGR-CL__-014: 0.2 m to 3 m or 3 m to 6 m (Dip switch option)
F3S-TGR-CL__-035: 0.2 m to 7 m or 7 m to 14 m (Dip switch option)
F3S-TGR-CL__-070: 0,2 m to 7 m or 7 m to 14 m (Dip switch option)
|
Detection capability
|
F3S-TGR-CL__-014: Opaque objects 14 mm in diameter
F3S-TGR-CL__-035: Opaque objects 35 mm in diameter
F3S-TGR-CL__-070: Opaque objects 70 mm in diameter
|
Effective aperture angle (EAA)
|
Within ±5°
|
Within ±2.5°
|
for the emitter and receiver at a detection distance of at least 3 m according to IEC 61496-2
|
Light source
|
Infrared LED (880 nm), power dissipation <3 mW, Class 1 per EN 60825-1
|
Supply voltage
|
24 VDC±20%, according EN 60204-1 able to cover a drop of voltage of at least 20 ms
|
OSSD
|
2 PNP transistor outputs, load current 2 × 250 mA max
|
Series connection
|
Number of connections: One master and one slave safety light curtain
Total number of beams ≤ 336
Maximum interconnect cable length: 900 mm
|
Test functions
|
Self test (after power ON and during operation)
|
Safety-related functions
|
All models with dip-switch setup for external device monitoring, interlock function, range setting (short and long range) and optical or wired sync.
Advanced models with selectable pre-reset function, T-, L-or X- muting function (timeout muting), blanking, single / double brake function and muting lamp integrated (only for the non master-slave systems)
|
Response time
|
ON to OFF: 14 ms to 103 ms
|
Ambient temperature
|
Operating: -10 to 55°C, Storage: -25 to 70°C (no icing, no condensation)
|
Ambient humidity
|
95% not condensing
|
Degree of protection
|
IP 65 (IEC 60529)
|
Materials
|
Housing: Painted aluminum, Yellow, RAL 1018
Front Window: Acrylic Lexan
Red end cap: PA6 (Standalone models),
Transparent end cap: PC (Advanced standalone models),
Die cast aluminum (Master-, Slave models)
Sealing Gasket: EPDM
Mounting Bracket: Cold rolled Steel
|
Suitable for safety control systems
|
PLc (ISO 13849-1)
|
PLe (ISO 13849-1)
|
Category
|
Categorie 2
|
Categorie 4
|
PFHd
|
2,5 × 10 -9
|
Proof test interval
|
every 20 years
|