NX-series Communication Gateway Unit
Unit type | Appearance | Supported communications protocol | Number of communications connectors | Network variables | Unit version | Order code |
---|---|---|---|---|---|---|
Communication Control Unit |
EtherNet/IP | 3 | 2 | Ver. 1.01 | NX-CSG320 |
NX-series Safety Control Units
Safety CPU Units
Unit type | Appearance | Specifications | Unit version | Order code | |||
---|---|---|---|---|---|---|---|
Maximum number of safety I/O points | Program capacity | Number of safety I/O connections | I/O refreshing method | ||||
Safety CPU Unit (NX-SL5⬜⬜⬜) |
1024 points | 2048 KB | 128 | Free-Run refreshing | Ver. 1.3 | NX-SL5500 | |
2032 points | 4096 KB | 254 | NX-SL5700 |
Safety Input Units
Unit type | Appearance | Specifications | Unit version | Order code | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Number of safety input points |
Number of test output points |
Internal I/O common |
Rated input voltage |
OMRON special safety input devices |
Number of safety slave connections |
I/O refreshing method |
||||
Safety Input Units | 4 points | 2 points | Sinking inputs (PNP) | 24 VDC | Cannot be connected. |
1 | Free-Run refreshing | Ver. 1.1 | NX-SIH400 | |
8 points | Cannot be connected. |
Ver. 1.0 | NX-SID800 |
Safety Output Units
Unit type | Appearance | Specifications | Unit version | Order code | |||||
---|---|---|---|---|---|---|---|---|---|
Number of safety output points |
Internal I/O common |
Maximum load current | Rated voltage |
Number of safety slave connections |
I/O refreshing method |
||||
Safety Output Units | 2 points | Sourcing outputs (PNP) |
2.0 A/point, 4.0 A/Unit at 40°C, and 2.5 A/Unit at 55°C
The maximum load current depends on the installation orientation and ambient temperature. |
24 VDC | 1 | Free-Run refreshing | Ver. 1.0 | NX-SOH200 | |
4 points | 0.5 A/point and 2.0 A/Unit | NX-SOD400 |
Automation Software Sysmac Studio
Please purchase a DVD and required number of licenses the first time you purchase the Sysmac Studio. DVDs and licenses are available individually. Each model of licenses does not include any DVD.
Product name | Specifications | Number of licenses | Media | Order code |
---|---|---|---|---|
Sysmac Studio Safety Edition Ver. 1.⬜⬜ |
Sysmac Studio Safety Edition is a license including necessary setting functions for the safety control system.
Note:This product is a license only. You need the Sysmac Studio Standard Edition DVD media to install it.
|
1 license | – | SYSMAC-FE001L |
Sysmac Studio Standard Edition Ver. 1.⬜⬜ |
The Sysmac Studio is the software that provides an integrated environment for setting, programming, debugging and maintenance of machine automation controllers including the NJ/NX-series CPU Units, NY-series Industrial PC, EtherCAT Slave, and the HMI.
Sysmac Studio runs on the following OS. Windows 7(32-bit/64-bit version)/8(32-bit/64-bit version)/8.1(32-bit/64-bit version)/10(32-bit/64-bit version) |
– (Media only) | DVD | SYSMAC-SE200D |
Optional Products
Product name | Specifications | Order code |
---|---|---|
Memory Card | SD memory card, 2 GB | HMC-SD291 |
SD memory card, 4 GB | HMC-SD491 | |
Unit/Terminal Block Coding Pins | For 10 Units (Terminal Block: 30 pins, Unit: 30 pins) | NX-AUX02 |
Product name | Specifications | Order code | |||
---|---|---|---|---|---|
No. of terminals | Terminal number indications | Ground terminal mark | Terminal current capacity | ||
Terminal Block | 8 | A/B | Provided | 10 A | NX-TBC082 |
8 | A/B | None | 10 A | NX-TBA082 | |
16 | A/B | None | 10 A | NX-TBA162 |
Accessories
Communication Control Unit Accessories
Product name | Remark | Order code |
---|---|---|
End Cover | One End Cover is provided with the Communication Control Unit. | NX-END02 |
Specifications
Regulations and Standards
NX-series Safety Control Units
Certification body | Standards | |
---|---|---|
TÜV Rheinland | EN ISO 13849-1EN ISO 13849-2IEC 61508 parts 1-7IEC/EN 62061IEC/EN 61131-2 | IEC 61326-3-1IEC 61131-6 |
UL | NRAQ (UL61010-1, and UL 61010-2-201)NRAG (ANSI/ISA 12.12.01, or UL 121201)NRAQ7 (CSA C22.2 No. 61010-1, and CSA C22.2 No. 61010-2-201)FSPC (IEC 61508 and ISO 13849) |
The NX-series Safety Control Units allow you to build a safety control system that meets the following standards.
– Requirements for SIL 3 (Safety Integrity Level 3) in IEC 61508, IEC/EN 62061, (Functional Safety of Electrical/Electronic/Programmable Electronic Safety-related Systems)
– Requirements for PLe (Performance Level e) and for safety category 4 in EN ISO13849-1The NX-series Safety Control Units are also registered for RCM, EAC, and KC compliance.
NX-series Communication Control Unit
Certification body | Standards |
---|---|
UL | NRAQ (UL61010-1, and UL 61010-2-201)NRAG (UL 121201) |
The NX-series Communication Control Units are also registered for RCM, EAC, and KC compliance.
General Specifications
Item | Specifications | |
---|---|---|
Enclosure | Mounted in a panel (open) | |
Grounding method | Ground to 100 Ω or less | |
Operating environment |
Ambient operating temperature | 0 to 55°C |
Ambient operating humidity | 10% to 95% (with no condensation or icing) | |
Atmosphere | Must be free from corrosive gases. | |
Ambient storage temperature | −25 to 70°C (with no condensation or icing) | |
Altitude | 2,000 m max. | |
Pollution degree | 2 or less: Conforms to JIS B3502 and IEC 61131-2. | |
Noise immunity | Conforms to IEC 61131-2. 2 kV on power supply line |
|
Insulation class | Class III (SELV) | |
Overvoltage category | Category II: Conforms to JIS B3502 and IEC 61131-2. | |
EMC immunity level | Zone B | |
Vibration resistance | Conforms to IEC 60068-2-6. 5 to 8.4 Hz with 3.5-mm amplitude 8.4 to 150 Hz, acceleration of 9.8 m/s2 100 minutes each in X, Y, and Z directions (10 sweeps of 10 min each = 100 min total) |
|
Shock resistance | Conforms to IEC 60068-2-27. 147 m/s2, 3 times each in X, Y, and Z directions |
|
Insulation resistance | 20 MΩ between isolated circuits (at 100 VDC) | |
Dielectric strength | 510 VAC for 1 min between isolated circuits, leakage current: 5 mA max. | |
Installation method | DIN Track (IEC 60715 TH35-7.5/TH35-15) |
Communication Control Unit
Unit name | Communication Control Unit | |
Model | NX-CSG320 | |
Indicators | [RUN] indicator, [ERROR] indicator, [BUSY] indicator, [SD PWR] indicator, [SD BUSY] indicator, [NS] indicator × 2, [L/A] indicator, [L/A 2A] indicator, [L/A 2B] indicator, [TS] indicator, [UNIT PWR] indicator, [I/O PWR] indicator | |
Hardware switch settings | [IP ADDRESS 1] Switch (x16, x1), [IP ADDRESS 2] Switch (x16, x1), DIP Switch
Factory default |
|
Dimensions | 72 × 100 × 90 mm (W × H × D) | |
Weight | 390 g | |
Number of NX Units that you can connect | 32 units or less | |
Number of communications that can be set between NX Units | 254 ports max. | |
Unit power supply | Power supply voltage | 24 VDC (20.4 to 28.8 VDC) |
Unit power consumption | 5.95 W | |
Inrush current | For cold start at room temperature: 10 A max./0.1 ms max. and 2.5 A max./150 ms max. |
|
Current capacity of power supply terminal | 4 A | |
Isolation method | No isolation: Between the Unit power supply terminal and internal circuit | |
Power supply to the NX Unit power supply |
NX Unit power supply capacity | 10 W max. |
NX Unit power supply efficiency | 80% | |
Isolation method | No isolation: Between the Unit power supply terminal and NX Unit power supply | |
I/O power supply to NX Units |
Power supply voltage | 5 to 24 VDC (4.5 to 28.8 VDC) |
Maximum I/O power supply current | 4 A | |
Current consumption from I/O power supply | 10 mA max. (24 VDC) | |
External connection terminals | Screwless clamping terminal block (8 terminals) | |
Terminal connection diagram | UV/UG: Unit power supply terminals IOV/IOG: I/O power supply terminals |
|
Accessories | End cover (NX-END02): 1 pc. | |
Installation orientation and restrictions | Only upright installation orientation |
Built-in EtherNet/IP Port Specifications
The following table shows the specifications of the built-in EtherNet/IP port of the Communication Control Unit.
Item | Specifications | |
---|---|---|
NX-CSG-⬜⬜⬜ | ||
Communications protocol | TCP/IP or UDP/IP | |
Supported services | Sysmac Studio connection, tag data links, CIP message communications, FTP server, automatic clock adjustment (NTP client), SNMP (agent), DNS (client), BOOTP (client), TCP/UDP message service | |
Number of logical ports | 2 (With IP routing function) | |
Physical layer | 100Base-TX or 10Base-T (100Base-TX is recommended.) | |
Transmission specifications |
Media access method | CSMA/CD |
Modulation | Baseband | |
Transmission paths | Star form | |
Baud rate | 100 Mbps (100BASE-TX) | |
Transmission media | Shielded twisted-pair (STP) cable, Category 5, 5e or higher | |
Transmission distance | 100 m max. (distance between hub and node) | |
Number of cascade connections | The built-in switching ports support up to 50 nodes. There is no limitation when an external Ethernet switch is used. |
|
CIP Safety routing | Maximum number of routable CIP Safety connections |
254 total For multi-cast connections, 128 total |
Maximum routable Safety data length per connection |
32 bytes | |
CIP service: Tag data links (cyclic communications) |
Number of connections | 32/Logical ports (total of 64 with two logical ports) |
Packet interval (refresh cycle) |
1 to 10,000 ms in 1-ms increments | |
Packet intervals can be set independently for each connection. (Data is refreshed over the network at preset intervals and does not depend on the number of nodes.) |
||
Allowed communications bandwidth per Unit |
12,000 pps
Note:The heartbeat and CIP Safety routing are included.
|
|
Number of registrable tags | 1024/Logical ports (total of 2048 with two logical ports) |
|
Tag types | Network variables | |
Number of tags per connection (=1 tag set) |
32 (31 tags if Controller status is included in the tag set.) | |
Maximum link data size per node | 46,208 bytes/Logical ports 92,416 bytes total |
|
Maximum data size per connection | 1,444 bytes | |
Number of registrable tag sets | Data concurrency is maintained within each connection. | |
32 per port (1 connection = 1 tag set) (total of 40 with two logical ports) |
||
Maximum size of 1 tag set | 1,444 bytes (Two bytes are used if Controller status is included in the tag set.) |
|
Multi-cast packet filter | Supported. | |
CIP message service: Explicit messages |
Class 3 (number of connections) |
Connections: 16/Logical ports (total of 32 with two logical ports) (server only) |
UCMM (unconnected) |
Maximum number of clients that can communicate at one time: 16 per port (total of 32 with two logical ports)Maximum number of servers that can communicate at one time: 16 per port (total of 32 with two logical ports) |
|
TCP/UDP message service |
Maximum number of clients that can communicate at one time |
16 per port (total of 32 with two logical ports) |
Maximum message size | Request: 492 bytes Response: 496 bytes |
|
SNMP | Agent | SNMPv1, SNMPv2c |
MIB | MIB-II | |
EtherNet/IP conformance test | Conforms to CT14 | |
Ethernet interface | 10BASE-T or 100BASE-TX Auto negotiation or fixed settings |
Used TCP/UDP port numbers
Do not set the same port number for more than one TCP/UDP service.
Service | Type | Port number | Remarks |
---|---|---|---|
Tag data links | UDP | 2222 | Fixed values |
Used by system | UDP | 2223, 2224 | |
TCP | 9610 | ||
CIP messages | TCP | 44818 | |
FTP client (Data transfer port) | TCP | 20 | |
DNS client | TCP/UDP | 53 | |
BOOTP client | UDP | 68 | |
HTTP server | TCP | 80 | |
Used by system, other | TCP/UDP | 9600 | You can change the port number in the Unit Settings on the Sysmac Studio. |
FTP client (Control port) | TCP | 21 | |
TCP/UDP message service | TCP/UDP | 64000 | |
NTP client | UDP | 123 | |
SNMP agent | UDP | 161 | |
SNMP trap | UDP | 162 |
Safety Control Units
Safety CPU Units NX-SL5500/SL5700
Unit name | Safety CPU Unit | |
---|---|---|
Model | NX-SL5500 | NX-SL5700 |
Maximum number of safety I/O points | 1024 points | 2032 points |
Program capacity | 2048 KB | 4096 KB |
Number of safety master connections | 128 | 254 |
Number of CIP Safety originator connections | 128 | 254 |
Number of CIP Safety target connections | 4 | 4 |
Number of originators that can be connected with a multi-cast connection |
8 | 8 |
Number of FSoE master connections | 128 | 254 |
I/O refreshing method | Free-Run refreshing | |
External connection terminals | None | |
Indicators | [TS] indicator, [NS] indicator, [FS] indicator, [P ERR] indicator, [RUN] indicator, [VALID] indicator, [DEBUG] indicator, seven-segment indicator |
[TS] indicator, [NS] indicator, [FS] indicator, [P ERR] indicator, [RUN] indicator, [VALID] indicator, [DEBUG] indicator, seven-segment indicator |
Hardware switch settings | [SERVICE] switch, [SETTING] switch | [SERVICE] switch, [SETTING] switch |
Dimensions | 30 × 100 × 71 mm (W × H × D) | |
I/O power supply method | Not supplied. | |
Current capacity of I/O power supply terminals | No I/O power supply terminals | |
NX Unit power consumption | 3.35 W max. | |
Current consumption from I/O power supply | No consumption | |
Weight | 130 g max. | |
Installation orientation and restrictions | Installation orientation: Upright installation
Restriction : None. |
Safety Input Units NX-SIH400/SID800
Unit name | Safety Input Unit | |
---|---|---|
Model | NX-SIH400 | NX-SID800 |
Number of safety input points | 4 points | 8 points |
Number of test output points | 2 points | 2 points |
Internal I/O common | PNP (sinking inputs) | |
Rated input voltage | 24 VDC (20.4 to 28.8 VDC) | |
OMRON special safety input devices |
Can be connected. | Cannot be connected. |
Number of safety slave connections |
1 | |
I/O refreshing method | Free-Run refreshing | |
External connection terminals | Screwless clamping terminal block (8 terminals) | Screwless clamping terminal block (16 terminals) |
Indicators | [TS] indicator, [FS] indicator, [IN] indicator, [IN ERR] indicator | [TS] indicator, [FS] indicator, [IN] indicator, [IN ERR] indicator |
Safety input current | 4.5 mA TYP. | 3.0 mA TYP. |
Safety input ON voltage | 11 VDC min. | 15 VDC min. |
Safety input OFF voltage/OFF current |
5 VDC max., 1 mA max. | |
Test output type | Sourcing outputs (PNP) | |
Test output load current | 25 mA max. | 50 mA max. |
Test output residual voltage | 1.2 V max. (Between IOV and all output terminals) | |
Test output leakage current | 0.1 mA max. | |
Dimensions | 12 × 100 × 71 mm (W × H × D) | |
Isolation method | Photocoupler isolation | |
Insulation resistance | 20 MΩ min. between isolated circuits (at 100 VDC) | |
Dielectric strength | 510 VAC for 1 min between isolated circuits, leakage current: 5 mA max. | |
I/O power supply method | Power supplied from the NX bus | |
Current capacity of I/O power supply terminals |
No applicable terminals. | |
NX Unit power consumption | Connected to a CPU Unit or a Communication Control Unit 1.10 W max.Connected to a Communications Coupler Unit 0.70 W max. | Connected to a CPU Unit or a Communication Control Unit 1.10 W max.Connected to a Communications Coupler Unit 0.75 W max. |
Current consumption from I/O power supply |
20 mA max. | |
Weight | 70 g max. | |
Circuit layout | ||
Terminal connection diagram | Si0 to Si3: Safety input terminals T0 and T1: Test output terminalsRefer to User’s manual (Cat. No. Z395) for details. |
Si0 to Si7: Safety input terminals T0 and T1: Test output terminalsRefer to User’s manual (Cat. No. Z395) for details. |
Installation orientation and restrictions |
Installation orientation:
Restrictions: Maximum ambient temperature is 50°C for any orientation other than upright installation. |
|
Protective functions | Overvoltage protection circuit and short detection (test outputs) |
Safety Output Units NX-SOH200/SOD400
Unit name | Safety Output Unit | |
---|---|---|
Model | NX- SOH200 | NX- SOD400 |
Number of safety output points | 2 points | 4 points |
Internal I/O common | PNP (sourcing outputs) | |
Maximum load current | 2.0 A/point 4.0 A/Unit at 40°C 2.5 A/Unit at 55°CThe maximum load current depends on the installation orientation and ambient temperature |
0.5 A/point and 2.0 A/Unit |
Rated voltage | 24 VDC (20.4 to 28.8 VDC) | |
Number of safety slave connections |
1 | |
I/O refreshing method | Free-Run refreshing | |
External connection terminals | Screwless clamping terminal block (8 terminals) | |
Indicators | [TS] indicator, [FS] indicator, [OUT] indicator, [OUT ERR] indicator |
[TS] indicator, [FS] indicator, [OUT] indicator, [OUT ERR] indicator |
Safety output ON residual voltage | 1.2 V max. (Between IOV and all output terminals) | |
Safety output OFF residual voltage | 2 V max. (Between IOG and all output terminals) | |
Safety output leakage current | 0.1 mA max. | |
Dimensions | 12 × 100 × 71 mm (W × H × D) | |
Isolation method | Photocoupler isolation | |
Insulation resistance | 20 MΩ min. between isolated circuits (at 100 VDC) | |
Dielectric strength | 510 VAC for 1 min between isolated circuits, leakage current: 5 mA max. | |
I/O power supply method | Power supplied from the NX bus | |
Current capacity of I/O power supply terminals |
IOG: 2 A max./terminal | IOG (A3 and B3): 2 A max./terminal IOG (A7 and B7): 0.5 A max./terminal |
NX Unit power consumption |
|
|
Current consumption from I/O power supply |
40 mA max. | 60 mA max. |
Weight | 65 g max. | |
Circuit layout | ||
Terminal connection diagram | So0 and So1: Safety output terminals IOG: I/O power supply 0 VRefer to User’s manual (Cat. No. Z395) for details. |
So0 to So3: Safety output terminals IOG: I/O power supply 0 VRefer to User’s manual (Cat. No. Z395) for details. |
Installation orientation and restrictions |
Installation orientation:
Restrictions: |
Installation orientation:
Restrictions: |
Protective functions | Overvoltage protection circuit and short detection (test outputs) |